Mineral Insulated Cable - AerOpak®

MI Thermocouple Cable Furnace Aeropak Cable Image

 

MI Cable Special Limits Of Error As Defined in ASTM E-230

Mineral Insulated Cable High Purity Magnesium Oxide (MgO) Insulation 99.4% Pure

Our product line of AerOpak® Mineral Insulated cable can be used under the most severe conditions that can destroy other types of thermocouple cable. Based on our rugged construction and with a large variety of sheath materials available, AerOpak® cable can be used in corrosive conditions up to the maximum range of the materials selected.

AerOpak® can be supplied in long lengths and can be formed or bent to a radius equal to twice the sheath diameter without loss of integrity. It can easily be welded or brazed to other metals when proper techniques are used.

Special non-destructive testing is available on in-process and finished thermocouple cable. Types of test available include Thermocouple Temperature Calibration, Radiography, Liquid Penetrant, Helium Leak, Dimensional, and Insulation Resistance. ARi standards are traceable to the National Institute of Standards and Technology (NIST).

With our manufacturing capabilities, we can produce high quality AerOpak mineral insulated cable with outside sheath diameters from 0.020" to 0.750". Metric sizes, custom sizes, and heavy wall thickness cable is available on request.

Please contact us for further information or any special requirements you may have. 

 

Cross Sectional Aeropak Picture

 

GENERAL SPECIFICATIONS

Outside Sheath Diameter ±0.002" (±0.05mm) or ±1% of nominal diameter, whichever is greater.
Wall Thickness ±0.0015" (±0.04mm) or ±15% of nominal wall thickness, whichever is greater, 10% of sheath diameter as a minimum.
Wire Diameter ±0.001" (±0.03mm) or 10% of nominal wire diameter, whichever is greater, 15% of sheath diameter as a minimum.
Calibration To meet special limits of error as defined in ASTM-E230

 

Part Numbering example

 

 

 

MATERIALS

WIRE TYPES

Wire Calibration ARI
Symbol

Temperature Range

ºC.

ºF.
Chromel - Alumel K 0 to 1260 32 to 2300
Chromel - Constantan E 0 to 870 32 to 1600
Iron - Constantan J 0 to 760 32 to 1400
Copper - Constantan T 0 to 370 32 to 700
Nicrosil - Nisil N 0 to 1260 32 to 2300

 

SHEATH MATERIALS
Material ARi
Symbol
Melting Temp. Max. Temp. In Air
ºF ºC ºF ºC
AISI 304 ST/ST A 2550 1400 1650 900
AISI 310 ST/ST D 2550 1400 2000 1090
AISI 316 ST/ST C 2500 1370 1650 900
AISI 347 ST/ST F 2550 1400 1650 900
AISI 446 ST/ST AG 2600 1430 2000 1090
Inconel 600 B 2470 1350 2000 1090
Hastelloy X V 2300 1260 2200 1200

 

INSULATION
High purity Magnesium Oxide (MgO), 99.4% minimum purity.

Standard AerOpak Mineral Insulated cable is normally available from our inventory for immediate shipment. Call or email for details!  