Aeropak Specifications


Conductor Cable Conductor Cable 2

 

SHEATH DIAMETERS and DIMENSIONS

ARi
Symbol

Sheath 
Diameter
Wall
Thickness
Conductor
Diameter
Normal Mfg.
Length
in mm in mm in mm ft meters
K .500 12.7 .072 1.83 .080 2.03 30 9.1
I .375 9.55 .057 1.45 .063 1.6 55 17
G .313 8.00 .048 1.22 .051 1.30 85 26
F .250 6.35 .038 .97 .042 1.07 135 41
E .188 4.75 .028 .71 .032 .81 240 73
D .125 3.18 .020 .50 .021 .053 560 171

 

SHEATH MATERIALS

Sheath
Material
ARi
Symbol
Melting Point Useable Temp. 
in Air
ºF ºC ºF ºC

347 St/St

F

2550 1400 1650 900
Inconel 600 (3) B 2570 1410 2100 (1) 1150
304 St/St A 2550 1400 1650 (2) 900
310 St/St D 2570 1410 2100 1150
316 St/St C 2550 1400 1650 900

1 Not recommended for use in sulfur atmosphere
2 Do not use in 800 to 1300ºF. temperature range due to intergranular precipitation.
3 Trademark of International Nickel Corp.

 

CONDUCTOR MATERIALS (SYMBOLS and RESISTANCE at 20º (68ºF.)
Conductor Size mm .50 .56 .66 .81 .96 1.00 1.30 1.62 2.03
inches .020 .022 .026 .032 .038 .040 .051 .064 .080
Gauge 24 23 22 20 19 18 16 14 12
Material ARi Symbol

Resistance, Ohms/Meter

304 St/St 304 3.5 2.9 2.2 1.4 .98 .88 .54 .34 .21
347 St/St 347 3.6 3.0 2.3 1.4 1.0 .90 .55 .35 .22
Inconel 600 (1) INC 5.0 4.4 3.0 2.0 1.4 1.3 .78 .50 .32
Oxygen Free Copper CUOFL .083 .068 .050 .032 .023 .021 .013 .008 .005
Nickel Low Carbon NIL .50 .41 .30 .20 .14 .13 .077 .049 .031
Constantan AQ 2.4 2.0 1.5 .93 .66 .59 .37 .23 .151
Chromel (2) KP 3.5 2.9 2.2 1.4 .98 .88 .54 .34 .218
Alumel (3) AY 1.5 1.2 .92 .58 .41 .37 .23 .14 .091
27% Ni Clad Copper INCU27 .13 .10 .073 .040 .035 .031 .019 .012 .008
1 Trademark of International Nickel Corp.
2 Trademark of Hoskins Mfg. Corp.
3 Trademark of Hoskins Mfg. Corp.

 

Contact ARi for further information and any special requirements you may have.